Infortrend F16F-R2021

Infortrend F16F-R2021

3TB Fc-Fc RAID Price: $7995

Add to cart

View Cart | Check Out

3 TERABYTE ( 2952GB)  STORAGE SOLUTION

12X146GB 15K / 4x300GB 10K FIBRE CHANNEL HARD DRIVES

This system was purchased new for rental use but was never put in service, excellent condition, cost as new was 25K.

FEATURES:

F16F-R2021 REDUNDANT CONTROLLER



End-to-end I/O performance of the F16F-R2021 achieves 725MB per second (MBps) sequential reads and 487MBps sequential writes in RAID5 configuration
Full-featured single or redundant controller(s) with six (6) FC-2G channels; transfer rate up to 2Gbps each
Twelve (12) 2Gbps Fibre ports; four (4) are host/drive adjustable
Highest redundancy level with separate host and drive I/O boards
RAID controller supports up to 2GB DDR RAM DIMM module
Support for up to 224 drives by cascading up to thirteen (13) JBOD enclosures SAN-ready subsystem in an enhanced modular enclosure provides daisy chaining and clustering capabilities


TECHNICAL SPECIFICATIONS:

Specifications
  RAID
  Multiple arrays configurable with dedicated or global hot spares
  Supports RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
  Infortrend Smart Technologies
 
  • IOSmart Technology
  • DrvSmart Technology
  • SysSmart Technology
  System Components
  Redundant, hot-swappable components , designed for no single point of failure
 
  • One (1) EonStor enhanced 3U enclosure
  • Sixteen (16) hot-swappable drive trays
  • Two (2) front handles
  • One (1) RAID controller module in the F16F-S2021 or two (2) in the F16F-R2021
  • 512MB DDR RAM DIMM module pre-installed on each RAID controller
  • One (1) independent battery backup unit (BBU) in the F16F-S2021 or two (2) in the F16F-R2021
  • Two (2) hot-swappable, redundant, 460W power supply units (PSUs)
  • Two (2) hot-swappable, redundant cooling modules each with two (2) dual-speed fans
  • One (1) enclosure configuration card
  • Two (2) host connection modules
  • Two (2) drive loop expansion modules
  Host Interface
  Up to four (4) FC-2G host channels with bypass circuit embedded to eight (8) FC ports on separate I/O modules
  DIP switch and jumper switch settings to change host port attributes
  Auto-negotiate FC-AL, point-to-point, or switched fabric
  Concurrent I/O commands
  Tagged command queuing up to 256
  Variable stripe size per logical drive
  Optimization setting for random or sequential I/Os
  Drive Interface
  Up to four (4) FC-2G drive channels with bypass circuit embedded to eight (8) FC ports on two (2) separate drive loop expansion modules
  Sixteen (16) hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch Fibre disk drives
  Single dual-loop across sixteen (16) drives
  Automatic bad bad- sector reassignment
  Dedicated bandwidth to each connected drive
  Management
  Firmware-embedded utility via LCD keypad or RS-232C port
  Host-side SES emulation with pass-through to back-end SES emulation
  10/100 BaseT Ethernet for out-of-band management
  Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  Firmware-embedded Java-based RAIDWatch® Manager:
 
  • VT-100 terminal emulation via RS232 serial port
  • Telnet access via onboard Ethernet port
  • Cross-platform, remote administration with SSL
  • Out-of-band access via Ethernet
  • Centralized management to monitor and administer multiple RAID units on one screen
  Configuration Client for easy access to the configuration utility screen
  SNMP 2.0 MIBs with get and set commands
  SAN Management
  Up to 1024 LUNs (if sufficiently large memory is used with the proper settings)
  Indicators
  Onboard alarm is triggered when one of the following fails:
 
  • RAID controller module
  • Cooling module
  • Power supply unit
  • Hard drive
  • BBU module
  • Host connection module
  • Drive loop expansion module
  Module status LED indicators:
 
  • Three (3) per LCD panel
  • Two (2) per drive tray
  • Six (6) per RAID controller module
  • Two (2) per Ethernet port
  • One (1) per BBU module
  • Two (2) per cooling module
  • One (1) per PSU
  • One (1) per Fibre port on host connection module and drive loop expansion module
  Module failure alert through I²C bus
  Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, SMS short messages
  System alerts through Java-based RAIDWatch Manager
  Infortrend Smart Technologies
  Derived from more than ten years experience in RAID storage design, Infortrend's innovative firmware delivers Smart technologies that provide enhanced storage solutions for every customer environment, from small organizations to large enterprises. These technologies enhance I/O processing, drive handling, and system management.
 
  • IOSmart
    IOSmart allows for the flexible configuration of logical drives, logical volumes and logical partitions and ensures instant RAID availability via background logical drive initialization. Fibre loops' load balancing is provided within the subsystem. The firmware's embedded intelligent algorithms, such as Adaptive Write Policy and Guaranteed Latency I/O, improve sequential write performance and ensure the fast and continuous flow of data.
  • DrvSmart
    The DrvSmart utility provides an easy way to store data while keeping it safe. One of the main DrvSmart functions, Media Scan, retrieves data from degraded or damaged hard drives and handles low quality drives in both the degraded mode and during the rebuild process. Other DrvSmart features include disk cloning, drive roaming, SMART, transparent resetting of non-responsive hard drives, and RAID parity update tracking and recovery.
  • SysSmart
    In addition to RAID protection for the disk drives, Infortrend has introduced Auto Data Protection Mechanisms. These special SysSmart firmware functions ensure data safety by automatically switching to write-through data caching when abnormal subsystem conditions are detected such as a PSU/cooling module failure, low BBU or UPS battery charge, etc.
    By using the firmware to monitor and control the enclosure's dual-speed fans, the fan rotation speed is raised to a higher level when critical conditions are detected, e.g., a PSU or fan failure. Fan speed returns to the lower setting when normal operating status is restored.
    The ES F16F-R/S2021 can be monitored by variety of utilities and approaches. I2C internal serial bus, SAF-TE, and SES are seamlessly integrated into the comprehensive Java-based GUI RAIDWatch Manager. Component status, voltage and temperature readings, and system events are instantly revealed through the manager's graphical interface.
  Interfaces:
 
  • Twelve (12) FC ports, each using a short-wavelength adapter
  • Two (2) COM ports on each controller module for RS-232C serial port (38400, n, 8, 1) and UPS support
  • One (1) 10/100BaseT Ethernet port on each controller module
  Power Supply Module
  Two (2) redundant, hot-swappable power supplies with PFC
 
Input 100VAC at 10A, 240 VAC at 5A with PFC (auto-switching)
  47 to 63Hz
Output Maximum output: 460 Watts
  +12.0V 32A max.
  + 5.0V 32A max.
  + 3.3V 30A max.
Dimensions

248.9(D) x 128(W) x 82.1(H) mm (9.8 x 5 x 3.2 inches)

  Cooling Module
  Two (2) redundant, dual-fan cooling modules
 
Maximum Air Flow

High speed: 31.8 DFM
Low speed: 20.1 CFM

  Environmental Specifications
 

Operating Temperature

0° to 40°C

Non-operating Temperature

- 40º to 60ºC

Relative Humidity

5 to 95%, non-condensing

Altitude

Operating: 0 to 12,000 ft
Non-operating: 0 to 40,000 ft

  Dimensions:
 
  • Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
  • Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
  • Shipping box: 567(W) x 423(H) x 772(D) mm (22.3 x 16.7 x 30.4 inches)
  System weight
 

 

  • Net weight: 28.5kg (62.7 pounds)
•  Gross weight: 30.5kg (67.1 pounds)

 


SUPPORT DOCUMENTS, DOWNLOADS AND MANUALS:


There are no items in your shopping cart.

sign up for the advanced audio newsletter